DIMENSIONS
Thimble Diameter Micrometer Heads

DIMENSIONS

Thimble Micrometer Heads

SPECIFICATIONS
Metric

Order No. Range Accuracy Stem dia. Stem Spindle end Special features
148-503  

 

 

 

 

0 – 13mm

 

 

 

 

 

±2µm

 

 

 

 

 

9.5mm

Plain  

Flat

Standard
148-513 Stainless steel throughout
148-508 W/ clamp nut  

Standard

148-506 Plain*
148-504 W/ clamp nut*
148-853 Plain Spherical (SR4)
148-854 W/ clamp nut*
148-863 Plain  

Flat

Reverse reading
148-864 W/ clamp nut*
148-518** W/ clamp nut Stainless steel throughout
148-858** W/ clamp nut Spherical (SR4) Standard
148-866** Plain* Flat Reverse reading
148-856** Plain* Spherical (SR4) Standard
148-868** W/ clamp nut Flat Reverse reading

* with spindle lock ** made-to-order models

Inch

Order No. Range Accuracy Stem dia. Stem Spindle end Special features
148-501

0 – .5″

±.0001″

.375″

Plain

Flat

Standard
148-511** Stainless steel throughout
148-507** W/ clamp nut

Standard

148-505 Plain*
148-502 W/ clamp nut*
148-851 Plain Spherical (SR4)
148-852 W/ clamp nut*
148-861 Plain Flat Reverse reading
148-862 W/ clamp nut*

* with spindle lock ** made-to-order models

Technical Data
Graduation: 0.01mm or .001″
Spindle pitch: 0.5mm or .025″

DIMENSIONS
Micrometer Heads

Magnetic Stands

DIMENSIONS

Magnetic Stands

SPECIFICATIONS

Order No. Description Applicable holding stem dia. Magnetic force Remarks
7010-10 Magnetic stand ø6mm, ø8mm Approx. 600N —
7010S-10 Magnetic stand ø4mm, ø8mm, ø9.53mm (3/8”) Approx. 600N —
7011-10 Magnetic stand ø6mm, ø8mm Approx. 600N With fine adjustment
7011S-10 Magnetic stand ø4mm, ø8mm, ø9.53mm (3/8”) Approx. 600N With fine adjustment
7012-10 Magnetic stand ø6mm, ø8mm, ø9.53mm (3/8”) Approx. 600N —
7014-10 Mini magnetic  stand ø6mm, ø8mm Approx. 150N Without magnet ON/OFF
7014E-10 Mini magnetic  stand ø4mm, ø9.53mm (3/8”) Approx. 150N Without magnet ON/OFF
7033B Universal magnetic  stand ø6, ø8mm, ø9.53mm (3/8”) Approx. 600N With mechanical locking system
7031B Universal magnetic  stand ø6, ø8mm, ø9.53mm (3/8”) Approx. 300N With mechanical locking system
7032B Universal magnetic  stand ø6, ø8mm, ø9.53mm (3/8”) Approx. 600N With mechanical locking system

Dial Snap Gage
Note: The dial indicator and protection cover are optional.

SPECIFICATIONS
Metric

Order No. Range Parallelism Measuring force Recommended dial indicator (optional)
201-101 0 – 25mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-102 25 – 50mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-103 50 – 75mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-104 75 – 100mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-105 100 – 125mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-106 125 – 150mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-107 150 – 175mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-108 175 – 200mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-109 200 – 225mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-110 225 – 250mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-111 250 – 275mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)
201-112 275 – 300mm 5µm 15N±3N 2046SB (0.01mm reading), 2109SB-10 (0.001mm reading)

Inch

Order No. Range Parallelism Measuring force Recommended dial indicator (optional)
201-151 0 – 1” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-152 1 – 2” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-153 2 – 3” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-154 3 – 4” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-155 4 – 5” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-156 5 – 6” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-157 6 – 7” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-158 7 – 8” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-159 8 – 9” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-160 9 – 10” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-161 10 – 11” .0002” 15N±3N 2803SB-10 (.0001” reading)
201-162 11 – 12” .0002” 15N±3N 2803SB-10 (.0001” reading)

*1: Measuring force is that force present before an indicator is installed and is determined at the point where the spindle is retracted 1mm from the rest position.

DIMENSIONS

Dial Snap Gage

Optional accessories
Dial indicator
Dial protection cover: No.21DZA000
Refer to page C-45 for details.
Recommended dial indicators
No.2046SB: Dial indicator (Graduation: 0.01mm)
No.2109SB-10: Dial indicator (Graduation: 0.001mm)

Internal measurement
Internal Measurement Dial Caliper

SPECIFICATIONS
Metric

Order No. Range Graduation Range of opening*1 Dial face Accuracy Measuring force
209-125 6 – 18mm 0.01mm 5.8 – 18.2mm 0-100-100 ±40µm 2.0N or less
209-126 10 – 22mm 0.01mm 9.8 – 22.2mm 0-100-100 ±40µm 2.0N or less
209-127 20 – 32mm 0.01mm 19.8 – 32.2mm 0-100-100 ±40µm 2.0N or less
209-155 5 – 15mm 0.01mm 4.8 – 15.2mm 0-100 ±30µm 2.0N or less
209-156 10 – 20mm 0.01mm 9.8 – 20.2mm 0-100 ±30µm 2.0N or less
209-175 10 – 30mm 0.01mm 9.8 – 30.2mm 0-100-100 ±40µm 2.0N or less
209-176 20 – 40mm 0.01mm 19.8 – 40.2mm 0-100-100 ±40µm 2.0N or less

*1: Datum point setting is required (Reference gage available as an optional accessory).
*2: Range of opening is a value for reference. Accuracy is not guaranteed if the Dial Caliper Gage is used beyond the measuring range.
* Please note that this Dial Caliper Gage is only provided with standard models. Special size and special specification models are not supported.

DIMENSIONS

Internal Measurement Dial Caliper

Order No. A B
209-125 1.1 1.1
209-126 2.3 2.7
209-127 8.0 4.4

Internal Measurement Dial Caliper

Order No. A B L T
209-155 2.2 2.2 26 1.2
209-156 5.5 5.5 28 1.5

Internal Measurement Dial Caliper

Order No. A B T
209-175 5.5 5.5 1.5
209-176 10 10 2.0

Standard Type

Thickness Gages

High Accuracy Type

Thickness Gages

Standard Type

Thickness Gages

Lightweight Type (integrated molding of the bezel)

Thickness Gages

Lens thickness measurement

Thickness Gages

Tube thickness measurement

Thickness Gages

Groove depth measurement

Thickness Gages

Usage examples

Measuring paper thickness

Thickness Gages

Measuring thickness of a human hair

Thickness Gages

DIMENSIONS

Thickness Gages

Unit: mm

Optional Accessories
905338
: SPC cable (1m) for digital models

905409: SPC cable (2m) for digital models
02AZD790F: SPC cable for U-WAVE (160mm)
Digimatic Mini-Processor DP-1VR
Refer to page A-13 for details.

Input Tool
Convenient Interface Input Tools which enable the conversion of measurement data to keyboard signals and directly input them to cells in off-the-shelf spreadsheet software such as Excel.

(Refer to pages A-5 to A-6 for details.)

DIMENSIONS

Thickness Gages

Application examples

Thickness Gages

Note:Parallelism between the flat point and anvil
547-313: 10μm
7313: 5μm Concave lens Ball

DIMENSIONS

Thickness Gages

DIMENSIONS

Thickness Gages

Styli (for Metric Models Only*)
* Except for universal type dial test indicator (513-304G).

Test Indicators

ø0.5mm ball-point

Test Indicators

190547 (L=14.7mm)
190549 (L=20.9mm)
190654 (L=22.3mm)
190656 (L=44.5mm)

ø0.7mm ball-point

Test Indicators

190548 (L=14.7mm)
190550 (L=20.9mm)
190653 (L=22.3mm)
190655 (L=44.5mm)

ø1mm ball-point (Carbide)

Test Indicators

21CZA044 (L=12.8mm)
103017 (L=14.7mm)
103013
(L=20.9mm)
137558
(L=22.3mm)
137746
(L=36.8mm)
136235 (L=44.5mm)

ø2mm ball-point (Carbide)

Test Indicators

21CZA036 (L=12.8mm)
103010 (L=14.7mm)
103006 (L=20.9mm)
137557 (L=22.3mm)
129949 (L=36.8mm)
136013 (L=44.5mm)

ø2mm ball-point (Ruby)
Test Indicators

21CZA212 (L=12.8mm)
21CZA209 (L=14.7mm)
21CZA201 (L=20.9mm)
21CZA210 (L=22.3mm)
21CZA211 (L=44.5mm)

ø3mm ball-point (Carbide)

Test Indicators
21CZA045 (L=12.8mm)
103018 (L=14.7mm)
103014 (L=20.9mm)
137559 (L=22.3mm)
137747 (L=36.8mm)
136236 (L=44.5mm)

Spanner

Test Indicators
Stems with Knurled Clamp Ring

Test Indicators

Swivel Clamps

Test Indicators

Holding Bars

Test Indicators

Universal Holder

Test Indicators

21CZA233 (ø8mm stem)
21CZA231 (.25″ DIA. stem)
21CZA229 (ø6mm stem)

Centering Holder

Test Indicators

Pocket Type Dial Test Indicator

Pocket Type Dial Test Indicator

SPECIFICATIONS

Pocket Type Dial Test Indicator

DIMENSIONS

Pocket Type Dial Test Indicator

Pocket Type Dial Test Indicator

There are two types of Mitutoyo Dial Test Indicator: The non-clutch type (without a clutch lever) and the clutch type (with a two-position clutch lever)

Pocket Type Dial Test Indicator

In the non-clutch type, although the contact point may move either in the upward or downward direction, the pointer always rotates clockwise. In the clutch type, if the clutch lever is set in one position the contact point moves in the upward direction and the pointer rotates clockwise. Conversely, if the lever is set in the other position the contact point moves in the downward direction and the pointer rotates counterclockwise.

Set Configuration: Metric

Pocket Type Dial Test Indicator

Set Configuration: Inch

Pocket Type Dial Test Indicator

Pocket Type Dial Test Indicator

Universal Dial Test Indicator

SPECIFICATIONS

DIMENSIONS

Universal Dial Test Indicator

Set Configuration: Metric

Universal Dial Test Indicator

Set Configuration: Inch

Universal Dial Test Indicator

Optional Accessories
––––––: Swivel clamps (See page F-63.)
––––––: Holding bars (See page F-63.)
––––––: Stems (See page F-63.)
102824: Stylus, ø1mm ball contact (carbide)
102825: Stylus, ø2mm ball contact (carbide)
102826: Stylus, ø3mm ball contact (carbide)